|
|
 |
 |
|
Product Index ::
Automation Systems
:: Programmable Controllers ::
PLC-Based Process Controllers
|
CS1W-P[][][] Process Analog I/O Units
|
|
![CS1W-P[][][] Process Analog I/O Units](cs1w-p[][][]_small.jpg)
|

|
* Ordering information
* Specifications
* Configurations
* Dimensions, and etc
|
|
can be found in our PDF brochure.
|
|
Provides the Functionality of Isolators, Power Supplies, Signal
Converters, and Other Devices.
Ideal for Analog Signal Monitoring and Data Logging Systems.
-
The Analog Input Unit
converts analog input signals such as 1 to 5 V or 4 to 20 mA into
digital values, and takes the values scaled in industrial units, and
transfers it to the CPU Unit as the process value. Because of this, no
ladder program is required at the CPU Unit for scaling.
-
The Analog Output Unit
converts analog output set values from the CPU Unit to analog output
signals such as 4 to 20 mA or 1 to 5 V, and outputs them.
-
The built-in functions, such
as measurement value alarms, rate-of-change calculations, and square
roots, have enabled major savings in cost and space compared with
previous systems.
-
High-resolution Models and
8-point Input Models are also available. By combining the Units,
logging/monitoring systems can be constructed, or the Units can be used
together with LCBs/LCUs to construct complete process control systems.
-
Parameters can be easily
displayed and set in an easy-to-understand form without special tools.
|
|
Features |
|
Process Analog Input:
-
Up to eight analog inputs can be connected
for each Unit.
-
There is isolation between input channels,
so unwanted circuit paths between thermocouple inputs can be prevented.
(Except for CS1W-PTR01/ 02)
-
Output scaling (±32,000)
-
Process value alarms (HH, H, L, LL)
-
Input disconnection alarm
-
Rate-of-change calculation and alarm
-
Top/bottom/valley hold
(CS1W-PTS11/PTS12/PDC11 only)
Process Analog Output:
-
Up to four analog set values can be output
for each Unit.
-
All outputs are isolated.
-
Output rate-of-change limit
-
Output high/low limits
-
Output scaling (±32,000)
-
Control output answer input (CS1W-PMV01
only)
Isolated-type Pulse Input:
|
|
Applications |
 |
Reducing Cost and Saving Space
|
|
External devices such as converters,
isolators, and power supplies are unnecessary. Up to 640 words of multipoint
data logging, and data acquisition with a cycle time as short as 0.01 s in
an isolated-type Unit. |
|
A
Process Analog I/O Unit, which can receive direct sensor inputs, is mounted
to a SYSMAC CS-series PLC. In general, this configuration can reduce costs
by 1/2 and reduce the required space by 1/3 compared to conventional
systems. |
|
|
|

|
|
|
 |
Reducing Engineering Costs
|
|
Functionality is already built into the Unit,
so programming is easy. Furthermore, settings are easy to make with the
Process Analog I/O Unit Support Software. |
|

|
|
 |
Constructing a
High-reliability Monitoring System
|
|
Inputs are isolated |
|
Use an Isolated-type Input Unit in the data logging system if the monitoring
application requires very accurate data collection. These models provide
protection against data
inaccuracies due to external noise, grounding problems, or disconnection. |
|

|
|
 |
Using Inputs from Sensors in
the Existing System
|
|
A Wide Range of Models for Various Signals |
|
Process Analog I/O Units support various types of analog signal, such as
thermocouple input, resistance thermometer input (Pt100, JPt100, Ni508.4 Ω),
4 to 20-mA current input, 1 to 5-V voltage input, ±1-mA and 0 to 1-mA input
for power transducers, and 0 to 100-mV DC input. |
|

|
|
 |
Allowing for System Expansion
|
|
Add a Loop Control Board for Even Greater
Flexibility |
|
When expanding the controlled system, use a Loop Control Board that is
supported by the CS-series PLCs. With a Loop Control Board, function blocks
can be combined freely to provide the flexibility of special control
systems, such as cascade control, feed-forward control, and dead time
compensation control. |
|

|
|
 |
Providing Remote Maintenance
Capability
|
|
Easy Remote Monitoring when an OMRON PLC Is
Used |
|
If
the control system is built upon a SYSMAC CS-series PLC, remote maintenance
can be performed easily as shown below. |
|
|
|

|
|
|
|
top |
See Related Products:
![CS1W-LCB[]1 Inner Board](../thumbnail/CS1W-LCB[]1.jpg)
|
Inner Board
CS1W-LCB[]1
Loop Control Board for fully
integrated sequence and process control. |

|
Programmable
Controller
CS1H / CS1G
Highly functional PLC best fit for any
large scale and complex automation systems. |
|
|
 |
|